INSTALLATION, OPERATION & MAINTENANCE MANUAL
IOM-C-PRV
12-13
MODEL C-PRV
PRESSURE REDUCING REGULATOR
SECTION I
I. DESCRIPTION AND SCOPE
Model C-PRV is a pressure regulator used to control downstream (outlet or P
2
) pressure. Inlet and outlet sizes
are 1", 1-1/2", 2" and 3" with Tri-Clamp
®
tting connections. This regulator is only suitable for liquids and gases at
temperatures less than 300°F (149°C). Refer to Technical Bulletin C-PRV-TB for speci c design con di tions.
SECTION II
II. INSTALLATION
A. General:
1. An inlet block valve should always be installed
up stream of the regulator.
2. An outlet pressure gauge should be located
ap prox i mate ly ten pipe diameters down stream
and within sight.
3. All installations should include a downstream
re lief device if the inlet pressure could exceed
the pressure rating of any downstream equip-
ment.
4. Flow Direction: Install so ow enters through
the bottom connection and exits the side con-
nection.
5. Install with spring chamber (2) in the vertical
up position to allow for proper draining.
A. General:
1. Ensure that lock-open pin (10) and hitch pin
(15) are in proper po si tion. See Sec tion VII.
2. Con rm that the proper range spring is in di -
cat ed to be within the regulator by inspection
of the unit’s nameplate. Apply setpoint pres-
sures that are only within the stated range.
SECTION IV
IV. START-UP
III. PRINCIPLE OF OPERATION
A. General:
1. Movement occurs as pressure vari a tions reg is-
ter on the di a phragm. The registering pres sure
is the outlet, P
2
or downstream pres sure. The
range spring op pos es diaphragm move ment.
As the outlet pressure drops, the range spring
pushes the diaphragm down, opening the port;
as outlet pressure increases, the diaphragm
pushes up and the port opening closes.
2. A complete diaphragm failure will cause the
reg u la tor to fail open
SECTION III
CAUTION
Installation of adequate overpressure pro tec tion is
recommended to pro tect the reg u la tor from overpres-
sure and all down stream equip ment from damage
in the event of regulator failure.
CAUTION
The Model C-PRV should never be used as a shutoff
device.
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - MODEL C-PRV

INSTALLATION, OPERATION & MAINTENANCE MANUALIOM-C-PRV 12-13MODEL C-PRVPRESSURE REDUCING REGULATORSECTION II. DESCRIPTION AND SCOPEModel

Seite 2

IOM-C-PRV23. When stating direction of rotation of the nut or handle (6), the view is with respect to look ing down towards the spring chamber or its

Seite 3 - CAUTION

IOM-C-PRV35. Loosen thumbclamp screw (13) and remove. a. For Opt-80: 2 piece clamp (13A): Loosen and remove clamp nuts (13B), washers (13D), bolts (1

Seite 4 - VII. CLEANING PROCEDURE

IOM-C-PRV4Figure 2: Spring Chamber in Lock-Open PositionA. Pre-Sanitation:1. Owner should refer to owner’s op er at ing pro ce dures for system shut

Seite 5 - SECTION VIII

IOM-C-PRV5SECTION VIIINEW REPLACEMENT UNIT:Contact your local Cashco, Inc., Sales Rep re sen- ta tive with the Serial Number and Product code. With t

Seite 6 - Forged Body shown above

IOM-C-PRV6Figure 3Forged Body shown aboveSee the next page for Item Number Descriptions.

Seite 7

IOM-C-PRV7Figure 41" Investment Cast Red. Port shown above Item No. Description 1 Body 2 Spring Chamber 3 Pressure Plate 4 Spring Button 5 A

Seite 8

Cashco, Inc.P.O. Box 6 Ellsworth, KS 67439-0006PH (785) 472-4461Fax. # (785) 472-3539www.cashco.comemail: [email protected] in U.S.A. IOM-C-PR