INSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM)
IOM-HP-S-
DIFF
12-13
MODEL HP-1+6+S
HIGH PRESSURE DIFFERENTIAL
REDUCING REG U LA TOR
I. DESCRIPTION AND SCOPE
The Model HP-1+6+S is a heavy duty, high pres-
sure differential reducing regulator used to control
differential pressure between downstream outlet (P
2
)
pressure and a loading (P
LOAD
) pressure to the spring
chamber. This unit applies to Cashco drawing nos.
32911 (Non-NACE construction), 32909 (CS NACE
construction), or 32907 (SST NACE construction).
Sizes are 1/2", 3/4", and 1-1/2" (DN15, 20, and 40).
II. INSTALLATION
This unit was designed and is used almost exclusively on compressor and turbo ex pand er seal gas systems. REFER
TO COM PRES SOR / EX PAND ER MAN U FAC TUR ER'S MAN U AL FOR DETAILED IN STAL LA TION, START-UP
AND SHUTDOWN OF THIS UNIT. Install regulator in ac cor dance with direction of ow arrow cast on body (1).
SECTION III
III. PRINCIPLE OF OPERATION
1. The HP-1+6+S is used to main tain a con stant
differential pressure across the seals of a
com pres sor/expander. A dif fer en tial pres sure re-
duc ing reg u la tor senses the down stream or outlet
(P
2
) pres sure on the lower side of the diaphragm
and is opposed by the force of the range spring
plus an ad di tion al loading (P
LOAD
) pressure con-
nect ed to the spring cham ber. The loading (P
LOAD
)
pres sure plus the range spring (14) setting (P
SET
)
equals the outlet (P
2
) pres sure of the reg u la tor.
The range spring setting (P
SET
) is the differential
setting.
SECTION II
HP-1+6+S
DIFFERENTIAL SCHEMATIC
SECTION I
CAUTION A
NOT FOR STEAM SERVICE. NOT FOR OXYGEN SERVICE.
CAUTION
For welded installations, all internal trim parts, seals and
diaphragm(s) must be removed from reg u la tor body prior to
welding into pipeline. The heat of fusion welding will dam-
age non-metallic parts if not re moved. NOTE: This does
not apply to units equipped with extended pipe nip ples.
CAUTION
Installation of adequate overpressure pro tec tion is recom-
mended to pro tect the reg u la tor from overpressure and
all down stream equip ment from damage in the event of
regulator failure.
CAUTION
Option-1+6 contains single di a phragm con struc tion. In
the event of diaphragm fail ure, the process u id will mix
with the load ing uid. Please alert your rep re sen ta tive so
an al ter na tive product can be se lect ed.
This unit is most commonly applied to develop a con-
stant differential pressure across a rotating shaft seal
to provide proper sealing and lubricating conditions
over varying pressure ranges. Refer to Tech ni cal
Bulletin HP-S-DIFF-TB for design con di tions and
se lec tion rec om men da tions.
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1

INSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM) IOM-HP-S-DIFF 12-13MODEL HP-1+6+SHIGH PRESSURE DIFFERENTIAL REDUCING REG U LA

Seite 2 - CAUTION B

IOM-HP-S-DIFF2V. SHUTDOWNSECTION V SECTION IV* NOTE: Systems sequencing operations at startup, normal operation, failure mode(s), and shutdown must a

Seite 3

IOM-HP-S-DIFF36. Adjusting screw (6) o-ring inspection: a. With locknut (7) and closing cap (28) re moved, turn adjusting screw (6) CW as far as po

Seite 4

IOM-HP-S-DIFF4c. Lubricate adjusting screw (6) threads. Carefully re in stall the adjusting screw (6) up into the spring cham ber (2) by ro tat ing

Seite 5 - Piping Schematic for HP-1+6+S

IOM-HP-S-DIFF55. Clean debris from within the regulator body (1) cav i ty. Make certain the old cylinder gas ket (18) is cleaned out of the body (1)

Seite 6 - VII. TROUBLE SHOOTING GUIDE

IOM-HP-S-DIFF6SECTION VIIVII. TROUBLE SHOOTING GUIDEPossible Cause RemedyA. Oversized regulator; inadequate rangeability. A1.A2.A3.A4.A5.Check actual

Seite 7 - SECTION VIII

IOM-HP-S-DIFF7SECTION VIIIPossible Cause RemedyA. Plugged body spacer vent hole. A. Clean vent opening.B. Plugged piston balance port. B. Re move trim

Seite 8

Repair Item No. Description Parts 1 Body 2 Spring Chamber 3 Pressure Plate 4 Spring Button 5 Body Cap 6 Adjusting Screw 7 Lock Nut 9 Flange